EliteShiresProperty Services

Smoke and CO alarms

Smoke and carbon monoxide alarm rules for landlords

The smoke and CO alarm rules for rented homes in England, as written: which rooms, the day-one check, repairs, records, exemptions and the £5,000 penalty.

Key takeaways

  • You need a smoke alarm on every storey that has a room used as living accommodation. Bathrooms and toilets count as living accommodation, and halls and landings count as rooms.
  • You need a CO alarm in any lived-in room with a fixed combustion appliance, such as a boiler, gas fire or wood burner. Gas cookers are excluded.
  • Test every alarm on the day a new tenancy begins, and keep a record. Repair or replace a faulty alarm as soon as reasonably practicable after it is reported.
  • The regulations do not require hard-wired alarms. HMO licences and building work can set a higher standard.
  • The council can serve a remedial notice and fine up to £5,000 if you don't comply. That figure was unchanged when we checked in October 2026.
In this guide

In England, landlords must fit a smoke alarm on every storey with a room used as living accommodation, and a carbon monoxide alarm in any such room with a fixed combustion appliance other than a gas cooker. Alarms must be checked on the day each new tenancy begins and repaired once reported faulty (2015 Regulations, amended from 1 October 2022).

This guide sets out the rules as the regulations word them. Several popular pages are out of date on this subject. Some still describe CO alarms as only for solid fuel appliances, the position before October 2022. It is part of our landlord safety certificates checklist. We are EliteShires Property Services in Kenton, and we fit smoke and carbon monoxide alarms for landlords across Harrow, Kenton, Stanmore and Edgware.

What do the regulations actually require?

Regulation 4 of the 2015 Regulations sets three duties: a smoke alarm on every storey with living accommodation, a CO alarm in any lived-in room with a fixed combustion appliance other than a gas cooker, and a check on the day each new tenancy begins, with repairs once a fault is reported. The table sets them out in the regulations' own terms. The duties were last changed on 1 October 2022. A tidy-up on 1 May 2026 removed references to shorthold tenancies from the definitions, but the three duties were unchanged when we checked legislation.gov.uk in October 2026.

The three alarm duties for landlords in England (checked October 2026)

DutyWhat the regulation saysIn force since
Smoke alarmsA smoke alarm on each storey with a room used wholly or partly as living accommodation1 October 2015
Carbon monoxide alarmsA CO alarm in any room used wholly or partly as living accommodation that contains a fixed combustion appliance other than a gas cooker1 October 2022 (solid fuel only before then)
Checks and repairsEach alarm checked on the day a new tenancy begins; repaired or replaced, as soon as reasonably practicable, after a report that it is faultyDay-one check 2015; repair duty 1 October 2022

Three definitions in the regulations change how this works in a real house:

  • A bathroom or lavatory counts as living accommodation (regulation 4(2)). A boiler in a bathroom needs a CO alarm in that bathroom. A storey with only a bathroom still needs a smoke alarm.
  • A hall or landing counts as a room (regulation 4(4)). That is why the usual position for a smoke alarm is the hall and landing ceilings.
  • A fixed combustion appliance burns fuel of any type to generate heat. GOV.UK's booklet gives that definition. Gas boilers, oil boilers, gas fires and wood burners all count. A purely decorative fireplace that does not work is not one, in the department's view.
Where the minimum alarms go in a two-storey rental A two-storey house. A smoke alarm on the landing and in the ground-floor hall. Carbon monoxide alarms in the living room with a gas fire and in the bathroom with a boiler. No carbon monoxide alarm is needed in a kitchen whose only combustion appliance is a gas cooker. THE LEGAL MINIMUM IN A TWO-STOREY LET FIRST FLOOR Bedrooms Landing S Bathroom with boiler CO GROUND FLOOR Living room with gas fire CO Hall S Kitchen gas cooker only No CO alarm legally needed S Smoke alarm CO Carbon monoxide alarm Why these rooms One smoke alarm on each storey with living accommodation. A bathroom counts as living accommodation, so a boiler there needs a CO alarm. Gas cookers are excluded. Minimum under the 2015 Regulations. Licensed properties follow licence conditions; building work can need more.
The legal minimum in a typical two-storey let. A boiler in the bathroom needs a CO alarm there; a gas cooker on its own does not.

Does a gas cooker or a boiler need a carbon monoxide alarm?

A gas cooker on its own does not. A boiler does, if it is in a room used as living accommodation. Gas cookers are expressly excluded from the CO duty. Every other fixed appliance that burns fuel for heat is in scope, whether it runs on gas, oil, coal or wood.

Which common set-ups need a CO alarm under the regulations

Set-upCO alarm legally required?
Combi boiler in the kitchenYes, in the kitchen, if the kitchen is used as living accommodation
Boiler in the bathroomYes. Bathrooms count as living accommodation
Gas fire or wood burner in the living roomYes, in that room
Gas hob or gas cooker onlyNo
Boiler in a loft, garage or outbuilding nobody lives inNot required by the regulations, because the room is not living accommodation
Boiler in a cupboard off a lived-in room or hallA grey area. Ask the council, and see the tip below
Electric heating and electric cooking onlyNo

Do alarms have to be hard-wired?

No. The 2015 Regulations do not say what type of alarm to use, so battery alarms meet them. GOV.UK recommends smoke alarms to BS 5839-6 and carbon monoxide alarms to BS EN 50291. For battery alarms, it suggests sealed-for-life batteries. Heat detectors are not a substitute for smoke alarms.

Other rules can ask for more than the regulations do:

  • HMO licence conditions often set their own fire detection standard. Read your licence before choosing alarms.
  • Building work, such as a loft conversion or a rewire, has its own requirements. Your electrician or building control body will tell you what applies.
  • Existing mains-wired alarms should be kept working and replaced like for like. Swapping a wired system for battery alarms is a downgrade, even where the regulations would allow it.

Mains-wired and interlinked alarms are electrical work, so book an electrician for those. For battery alarms, a handyman visit is enough.

Where should smoke and carbon monoxide alarms go?

The regulations don't set positions, so follow the manufacturer's instructions. GOV.UK's general guidance is that smoke alarms usually go on the ceiling of a hall or landing. Carbon monoxide alarms usually go at head height, on a wall or shelf, about one to three metres from the appliance.

Some practical points we follow when fitting:

  1. Put the smoke alarm where the storey's escape route is, usually the hall and landing.
  2. Keep smoke alarms out of kitchens and away from bathroom doors, where cooking fumes and steam cause false alarms. Repeated false alarms tend to end with a battery being taken out.
  3. Fit the CO alarm in the same room as the appliance, not in the next room.
  4. A mezzanine is not a separate storey in the department's view. A split-level house is not covered by the guidance, so treat each level with rooms as a storey.

What must you do on the day a tenancy starts?

Check that every alarm works on the day a new tenancy begins, and keep a record of the check. A new tenancy is one granted on or after 1 October 2022. A tenancy that simply follows on with the same landlord, same tenant and the same or substantially the same property doesn't count. Check-in day is still the sensible time to test.

GOV.UK's booklet says landlords should keep a record of when alarms are tested. It suggests the tenant signs the inventory to confirm the alarms were tested and working. The booklet also suggests showing tenants how to test their alarms and how often.

What if a tenant reports a faulty alarm?

You must check it and repair or replace it as soon as reasonably practicable. This duty was added on 1 October 2022 and applies whenever a tenant, or someone acting for them, reports a fault. It covers both smoke and carbon monoxide alarms.

A few situations come up often:

  • A low-battery chirp. GOV.UK advises tenants to try a new battery first, then report the alarm if it still fails. A sealed-for-life alarm can't have its battery changed, so it needs replacing.
  • An alarm past its replace-by date. Most alarms carry a manufacturer's replace-by date. An expired alarm should be replaced. Retesting it is not enough.
  • A CO alarm sounding. Treat it as an emergency. A CO alarm sounding is not the same as an alarm being faulty, so don't assume it is a false alarm. The tenant should get out and call the gas emergency number. The appliance then needs a Gas Safe registered engineer before it is used again. We book gas safety checks with Gas Safe registered engineers.

Does the annual gas safety check cover your alarms?

No. The gas safety check covers the gas appliances, fittings and flues you provide. The alarm duty comes from different regulations. Many landlords assume the engineer's visit ticks both boxes. It doesn't, unless you ask for the alarms to be tested and recorded at the same visit. Combining them makes sense, and our engineers and handymen can do both on one booking.

Who is exempt from the alarm regulations?

Lodgers who share a kitchen or living room with the landlord, long leases, student halls, hotels, refuges, care and healthcare settings, low-cost home ownership and owner-occupiers are all outside the 2015 Regulations, according to GOV.UK's booklet. In detail:

  • Lodgers who share a kitchen or living room with the landlord or the landlord's family.
  • Long leases.
  • Student halls, hotels and refuges, care homes, hospitals and hospices, and other healthcare accommodation.
  • Low-cost home ownership homes, and owner-occupiers.

Social landlords have been covered since 1 October 2022. Houses and HMOs that need a licence are outside the regulations too, as the next section explains.

What changes if the property is licensed?

Houses and HMOs that need a licence are outside the 2015 Regulations altogether, whether or not the licence has been obtained. Instead, Schedule 4 of the Housing Act 2004 puts equivalent alarm requirements into every licence: a smoke alarm on each lived-in storey, a CO alarm in rooms with a fixed combustion appliance other than a gas cooker, both kept in proper working order, and a declaration to the council on demand. The licence conditions have no day-one check or report-and-repair wording, but testing at check-in is still the sensible way to keep alarms in working order.

In our area that covers Harrow's six selectively licensed wards, Brent's Kenton ward and Barnet's HMOs; our guide to licensing in Harrow, Brent and Barnet shows which applies to your address. A breach of a licence condition is a separate offence, now open to a civil penalty of up to £40,000. Our guide to landlord fines compares the penalties.

How does the council enforce the alarm rules?

Through a remedial notice, and then a penalty. If the council has reasonable grounds to believe you are in breach, it must serve a remedial notice within 21 days. You then have 28 days to take the action it specifies. If you don't, the council must arrange the work itself within 28 days, if the occupier consents. It can also charge a penalty of up to £5,000.

How a council enforces the alarm rules Four stages. The council serves a remedial notice within 21 days of deciding it has grounds. The landlord has 28 days to act. If the landlord does not, the council must arrange the work within 28 days with the occupier's consent, and can serve a penalty charge notice of up to 5,000 pounds within six weeks. FROM BREACH TO PENALTY: THE ENFORCEMENT STEPS STEP 1 Council has grounds It believes an alarm duty is being breached. STEP 2 Remedial notice Served within 21 days of that decision. You can make written representations within 28 days. STEP 3 28 days to act Fit, repair or replace the alarms named in the notice. This is the moment to book the work. STEP 4 If not done Council must arrange the work within 28 days, with consent. Penalty up to £5,000, notice within 6 weeks. Source: Smoke and Carbon Monoxide Alarm (England) Regulations 2015, regulations 5, 7 and 8. Houses and HMOs that need a licence are outside these rules and follow licence conditions instead.
How a council enforces the alarm duties under regulations 5, 7 and 8.

The £5,000 maximum is set by regulation 8. GOV.UK says it applies per breach. On legislation.gov.uk in October 2026, regulation 8 was unchanged by the Renters' Rights Act. That is lower than the £40,000 maximum for an EICR breach.

Where can you get alarms fitted or checked locally?

We fit, test and replace alarms on the same visit as other landlord work, and confirm the price, or the hourly rate and an estimate, before we attend. Book through our pages for handyman jobs in Harrow, alarm fitting in Kenton, handyman visits in Stanmore or small jobs in Edgware. If you are getting ready for a new tenancy, our guide to what to expect at a landlord safety inspection explains how a combined visit runs. Our list of documents to give tenants covers the paperwork at check-in. For every other check a let needs, go back to the full certificates checklist.

Sources

This is general guidance on the position in England, not legal advice.

Related services

Book the work this guide covers

Certificates and the trades that put right whatever they find, from one office on Kenton Lane.

  • Handyman

    The list of small jobs you have been putting off, done in one visit, at an hourly or half-day rate.

    Half or full dayOne visit for the list

  • Electrical Work

    Fault finding, consumer units, rewires, sockets, lighting and EICR remedial work, with the certificate for the work issued on completion.

    Same-day fault findingFixed price on defined jobs

  • Gas Safety Certificate

    An annual gas safety check on every gas appliance and flue you provide, by a Gas Safe registered engineer, with the record issued on the day.

    Record on the dayFixed price

In your area

Related guides

Book handyman work

Most quotes are settled on a two-minute call. Photos of the room, sent by WhatsApp, often let us price without a visit. Or send the form and we will call you back.

0203 667 1333
  1. We confirm the quote for your property
  2. We book a time slot that suits you or your tenant
  3. We work through the list and photograph the finished jobs
Thank you, your request has been sent. We will call you back on the number you gave, during our opening hours.

We use your details only to reply to this enquiry.

Visit the office

EliteShires Property Services
6 Station Parade, Kenton Lane
Harrow HA3 8SB

Call or WhatsApp

0203 667 1333
WhatsApp 07534 813123

Opening hours

Mon – Fri · 8:00 – 18:00
Saturday · 9:00 – 16:30
Sunday · Emergencies only

Chat on WhatsApp